Model of gen-set | NG50GF | NG80GF | NG100GF | NG150GF | NG180GF | NG220GF | NG240GF |
Gen-set Rated power | 50KW/ | 80KW/ | 100KW/ | 150KW/ | 180KW/ | 220KW | 240KW/ |
62.5KVA | 100KVA | 125KVA | 188KVA | 225KVA | /275KVA | 300KVA | |
Gen-set Standby power | 55KW/ | 88KW/ | 110KW/ | 165KW/ | 200KW/ | 242KW/ | 264KW/ |
68.75KVA | 110KVA | 132KVA | 206KVA | 250KVA | 302KVA | 330KVA | |
Diesel Engine | |||||||
Model | 4BTA3.9-G2 | 6BT5.9-G2 | 6BTA5.9-G2 | 6CTA8.3-G2 | 6CTAA8.3-G2 | 6LTAA8.9-G2 | NT855 |
Displacement(L) | 3.92 | 5.88 | 5.88 | 8.3 | 8.3 | 8.9 | 14 |
Compression ratio | 10.5 | 10.5 | 10.5 | 10.5 | 10.5 | 10.5 | 10.5 |
Bore and stroke(mm) | 102×120 | 102×120 | 102×120 | 114×135 | 114×135 | 114×145 | 140×152 |
Rated power(kW) | 55 | 95 | 117 | 179 | 201 | 242 | 261 |
Standby power | 61KW | 101KW | 128KW | 198KW | 222KW | 264KW | 291KW |
Alternator | |||||||
Model | MP-50-4 | MP-80-4 | MP-104-4 | MP-160-4 | MP-180-4 | MP-220-4 | MP-240-4 |
Rated output(KW/KVA) | 50/62.5 | 80/100 | 100/125 | 150/188 | 180/225 | 220/275 | 240/300 |
Rated voltage(V) | 400/240 | 400/239 | 400/240 | 400/239 | 400/240 | 400/240 | 400/240 |
Rated Current(A) | 90 | 144 | 180 | 270 | 324 | 396 | 432 |